Appliance Repair Elmwood Nebraska

Hometown Hero Appliance Repair Rated 5.0 out of 5 stars based on 3 customer reviews

We serviced a
KENMORE REFRIGERATOR
Model 795.79043313
Near Elmwood, NE 68349
Bryce
Job Details: 10/01/2024
Customer states unit is not cooling upon inspection. Verified complaint notice that freezer and fresh food temps are 65? as well as has a six beeps on the compressor for the error code basically meaning that the compressor is shot will be needing new system.
We serviced a
MAYTAG WASHER
Model MVWB766FW1
Near Elmwood, NE 68349
Ali
Job Details: 09/11/2024
During inspection unit had a communication error code. Gained access to the user interface and noticed corrosion buildup on the board. Cleaned all of the corrosion and reassembled the unit. Ran a diagnostic test and unit is now operating properly.Thanks for choosing Home Town Hero Appliance Repairs. Please leave us a review on Google or the link via your email for your FREE $10 gift card to Jimmy Johns. Ali!
We serviced a
WHIRLPOOL RANGE/COOKTOP EL
Model WFE515S0EW0
Near Elmwood, NE 68349
Derek F
Job Details: 08/14/2024
Upon inspection the ovens front glass had fallen out of the door. I found the two screws holding the handle were loose and allowed the glass to fall. The door is also missing two plastic supports that stabilize the front glass from the sides. Two new side supports would be needed to complete the repair.Thanks for choosing Hometown Hero Appliance Repair. Please leave us a review on Google or the link via your email for your FREE $10 gift card to Jimmy Johns. Derek!
We serviced a
LG REFRIGERATOR
Model LMXS28596S.ASTCNA1
Near Elmwood, NE 68349
Ali
Job Details: 05/13/2024
Tapped into system and got high side pressure at 24.4 and low side at 18.3 indicating a failed compressor. Unit will need the compressor, and drier replaced. I removed old compressor and drier from unit. I then installed and welded in new compressor and drier. Then proceeded to pressurize system with nitrogen to 120 psi. I checked all welds with bubble leak detector and no leaks were found. Next I vacuumed down the system for 15 minutes and achieved a 856 micron vacuum. After removing vacuum, pump the vacuum settled out at 1756 microns. Vacuum holding steady. I then recharged system with 56 g of r600 refrigerant. Unit is now running and beginning to blow cold air. Allow 24 hours for unit to cycle temps back down to normal. Job complete. Ali! ; dspstn on spec-tagged invntry: 1 ADH73150210 DRIER UV 1 ADL73762013 EVAP , and 1 TCA36811409 R600 TCA36811415
We serviced a
WHIRLPOOL WASHER
Model WFW9600TW01
Near Elmwood, NE 68349
Ali
Job Details: 03/26/2024
Upon arrival noticed that the power light was flashing with nothing happening and went ahead and gave the control board a hard restart and tested multiple times and machine is now operating properly Ali! ; dspstn on spec-tagged invntry: 1 WPW10415587 SWITCH-WL
G.J. Miller
Elmwood, Nebraska
05/15/2024
Very friendly, put customer at ease during very trying time. Knowledgeable, no short cuts, done right. Accompanying apprentice, studious and polite. Will call them again if needed. Appreciate good service, difficult to find these days.
Overall Experience
Pat
Elmwood, Nebraska
03/14/2024
Great service so efficient, polite, so pleased on everyone you have
Overall Experience
Doug
Elmwood, Nebraska
03/06/2024
Wonderful,so knowledgeable very polite, was able to fix it right away. Will tell others how great service was
Overall Experience