We serviced a
SAMSUNG DRYER
Model DVE45T6000W/A3
Near Central City, IA 52214
Dillon
Job Details: 02/15/2024
Customer says that the machine has been swapped out and was told that the appointment was canceled. Job complete.; dspstn on spec-tagged invntry: 1 6602-001655 BELT ( M ONLY ) 1 DC47-00016A THERMAL LIMITER , 1 DC93-00634A IDLER ASM , 1 DC96-00887C THERMAL FUSE W/ STAND , and 1 DC97-14486A HEATING ELEMENT COMPLETE(
We serviced a
GENERAL ELECTRIC REFRIGERATOR/TOP
Model GIE22JTNBRBB
Near Central City, IA 52214
Mike
Job Details: 02/22/2023
Ff 37-40 and fz 3-8* Installed new ice maker and and control. Ice-maker completed cycle and filled and compressor and fans came on when I turned control back on. Job complete.
We serviced a
GENERAL ELECTRIC REFRIGERATOR/TOP
Model GIE22JTNBRBB
Near Central City, IA 52214
Mike
Job Details: 02/21/2023
Unit is 0-5 in the freezer and 32-39 in ff section. Ice maker has been making at best 2-3 batches of ice per day. Called tech-line and they recommend the freezer be at least 50% full. At this time they are recommending replacing the ice maker. There is one in Des Moines and I will be back through the area tomorrow and will install the ice maker at that time. ; ordrng 1 WR30X30972 (Ice made)
We serviced a
GENERAL ELECTRIC REFRIGERATOR
Model GIE22JTNBRBB
Near Central City, IA 52214
Mike
Job Details: 02/09/2023
"Unit was 4-15 in freezer and 40-43 in fridge. Unit makes one batch of ice per day at best. Unit was cycled off when I arrived. After a few minutes it did kick on. Checked frost pattern and it took quite some time to develop a good frost pattern and was anywhere from -4 to 8 degrees after 20 minutes and I would expect closer to -10 across the entire evaporator. Checked system pressures and am getting-17 low side and 39 on the high side. Recovered refrigerant and pressurized with nitrogen did not find a leak anywhere in them system and pressure held perfectly. I installed process ports and vacuumed down the system and vacuum settled out and held perfectly as well, recharged system with the specified 44g and now pressures and -7 low side and 55 on the high side. Unit seems to have been undercharged from the factory. After just 10 minutes of running evaporator is at -10*. Job complete.; dspstn on spec-tagged invntry: 1 WPW10143759 UV DRIER (WPL)"