We serviced a
LG REFRIGERATOR
Model LFXS30726S.ASTCNA0
Near Lincoln, NE 68503
Ali
Job Details: 04/18/2024
"Tapped into system and got high side pressure at 141.8 and low side at -18.0 indicating a sealed system leak resulting in a system restriction. I reclaimed remaining refrigerant. Unit will need the compressor, drier, and fresh food evaporator replaced. I removed old compressor and drier from unit. I then installed and welded in new compressor and drier. I then removed old fresh food evaporator and welded in new one. I then proceeded to pressurize system with nitrogen to 150 psi. I checked all welds with bubble leak detector and no leaks were found. Next I vacuumed down the system for 20 minutes and achieved a 782 micron vacuum. After removing vacuum, pump the vacuum settled out at 802 microns. Vacuum held steady. I then recharged system with 4.76 oz of r134 ar refrigerant. Unit is now running and beginning to blow cold air. Allow 24 hours for unit to cycle temps back down to normal. Job complete."
We serviced a
WHIRLPOOL WASHER
Model n/a
Near Lincoln, NE 68506
Ali
Job Details: 04/18/2024
New pump locked up. Ordering a new pump; ordrng 1 W10876600 (Pump)
We serviced a
GE DISHWASHER
Model GDT550PGRWW
Near Lincoln, NE 68505
Ali
Job Details: 04/18/2024
"Spray arm knocking on the tub. Replaced loose spray arm. Tested unit, working best after repairs. Ali!"
We serviced a
LG REFRIGERATOR
Model LRFCS2503S
Near Lincoln, NE 68521
Ali
Job Details: 04/18/2024
"PCB was displaying 3 blinks, indicating a bad compressor. Unit will need the compressor, and drier replaced. I removed old compressor and drier from unit. I then installed and welded in new compressor and drier. Then proceeded to pressurize system with nitrogen to 170 psi. I checked all welds with bubble leak detector and no leaks were found. Next I vacuumed down the system for 20 minutes and achieved a 741 micron vacuum. After removing vacuum, pump the vacuum settled out at 1316 microns. Vacuum holding steady. I then recharged system with 57g of r600 refrigerant. Unit is now running and beginning to blow cold air. Allow 24 hours for unit to cycle temps back down to normal. Job complete.; dspstn on spec-tagged invntry: 1 ADL76521401 EVAP and 1 TCA37071511 COMPRESSOR"
We serviced a
JENNAIR OVENS ELECTRIC
Model JES9800CAF00
Near Lincoln, NE 68520
Ali
Job Details: 04/18/2024
Unit not getting up to temperature upon arrival. Removed rear panel and tested all switches and sensors to see if any were going out. Found the oven temp sensor was failing. Replaced oven temp sensor and calibrated unit. Unit working great after repairs. Ali! ; dspstn on spec-tagged invntry: 1 12001656 OVEN SENSOR LONG
Steve S
Lincoln, Nebraska
04/20/2024
Very friendly clean knowledgeable I recommend Ali as a great service tech.
Overall Experience
Lincoln, Nebraska
04/19/2024
Very professional. Knowledgeable
Overall Experience
Jon/sharon dexter
Lincoln, Nebraska
04/19/2024
Ali was very professional and thorough
Overall Experience
Ali
Ashland, Nebraska
04/18/2024
Ali and his apprentice sorry I forgot his name were very friendly and got the problem solved I will definitely call on home town hero’s for further assistance
Overall Experience
Dillon
Lincoln, Nebraska
04/18/2024
Overall Experience